Study on the Removal of COD from Soluble Cutting Fluids(SCF) Using Aluminium Electrode
장성호 Seona-ho Jang , 정영빈 Youna-been Jeong , 양승빈 Seung-bin Yang , 박제성 Je-sung Park , 박진식 Jin-sik Park , 류재용 Jae-yong Ryu , 김정득 Jeong-deuk Kim
Abstract
The purpose of this study using electrochemical treatment with aluminum electrode is to provide fundamental data of Soluble Cutting Fluids treatment in COD. The experimental results are as follows. Without NaCl, the removal rates of CODMn were 18.61%, 72.57% and 74.46% (40mins) at applied voltage of 5V, 10V, 15V for 60mins. Removal rates of CODcr were 23.26%, 90.41%, and 94.20% (40mins), respectively. The removal rates of COD increased with increasing the applied voltage. With NaCl of 5mM and lOmM, the removal rates of CODMn were 18.61%, 58.01% (40mins) and 78.71% on applied voltage 5v for 60min. Removal rates of CODcr were 23.26%, 72.92%, and 78.75%. With NaCl of 5mM and 10mM, the removal rates of CODMn were 72.57%, 69.01% (40mins) and 74.27% (30mins). on applied voltage 10v for 60min. Removal rates of CODcr were 90.41%, 85.71% (40mins), and 91.43% (30mins). The removal rates of COD increased with increasing the concentration of NaCl.
Key Words
Soluble Cutting Fluids, Electrochemical treatment, Aluminium electrode, COD