Artificial Copper Wastewater Removal Rate Tendency According to Impact Factor and Result of Continuous Operating Experiment by Using Aluminum Electrocoagulation
김진수 Jin Su Kim , 심재훈 Jae Hoon Shim , 이한슬 Han Seul Lee , 신총수 Chong Soo Shin , 이상철 Sang Cheol Lee , 이상일 Sang Ill Lee
Abstract
This study was conducted to evaluate the treatment of copper in wastewater by using electrocoagulation. Most of industrial wastewater has treated to physical and chemical methods because industrial wastewater has biologic toxic. Therefore, electrocoagulation belonging to the electrochemical method is being used in variety of industrial wastewater treatment. It shows mainly high removal efficiency of heavy metal and turbidity. In this study, it was evaluated to copper removal efficiency by pH, reaction time and current density through jar-test experiment. In case of pH, copper concentration was slightly decreased at higher than pH 4. In case of reaction time, copper removal efficiency was 91.6 % at reaction time in 4 minute and more than 98 % at reaction time in after 6 minute. In case of current density, copper removal efficiency was rapidly increased to 0.0058 A/cm2. Base on value of jar-test experiment, continuous operating of electrocoagulation experiment was applied the hydraulic retention time(HRT) 4 minute and current density 0.0167 A/cm2. pH of wastewater was not changed. Results, average copper removal efficiency was 74.7 % and maximum removal efficiency was 79.1 % while operating 110 minute.
Key Words
Electrocoagulation, Copper remove, Jar-test, Impact factor of electrocoagulation, pH, Reaction time, Current density
pdf view PDF