DOI : ,    Vol.21, No.6, 87 ~ 96, 2013
Title
Phosphorus and Nitrogen Removal of within Sewage Using Fe Electrode Caterpillar-type Electrolysis Device
김민규 Min Kyu Kim , 송영일 Young Il Song , 이성기 Seong Key Lee
Abstract
It was developed an electrolysis device-type with a Fe electrode caterpillar. which was improved some troubles of a Fe electrode. The T-P removal rate was investigated according to various operation conditions. The pH change was not shown greatly at each processes. The nitrogen and phosphorus removal rate appeared higher an electrode plate with 920 mm than 600 mm depth. It was shown higher removal rate with three electrode plate than two. The 920 mm of an electrode printing interval was higher in nitrogen and phosphorus removal rates than 740 mm, but the difference was not large. Phosphorus effluent concentration according to an electric current change appeared lower 9 A, 14 A than 22 A. The electric current is higher, phosphorus removal rate is high because the response of iron ion is more active. The nitrogen removal rate was 50.1∼84.2% and a phosphorus removal rate was 96.0∼99.6% in combined sewage treatment processes with night soil and livestock wastewater. The nitrogen removal rate was 77.8∼89.7% and phosphorus removal rate was 77.7∼95.9% in sewage treatment processes. A phosphorus removal rate is higher in case of combined sewage treatment, which was good enough in the removal of nitrogen and phosphorus, Removal rate was shown as BOD 91.7∼98.6%, COD 90.0∼95.9%, SS 93.7∼98.8% in combined sewage treatment process with livestock and night soil. The iron production according to an electric current change was shown higher in case of 22 A than 9 A. The electric current is higher, The T-P removal rate is high. because of increasing the iron ion reactivity.
Key Words
Electrolysis, Fe Electrode, Caterpillar type, Phosphorus Removal, Sewage Treatment
pdf view PDF